Guide

Indoor Grow Electricity Cost: The Simple Math

One formula, your utility rate and an honest wattage number will tell you what a grow adds to your bill, before you buy a single seed.

Guide · · 6 min read

Electricity is the running cost most indoor growers underestimate. The light is the main draw, but fans, heaters, dehumidifiers and pumps add up too, and the schedule you choose decides how many hours all of that runs.

The good news is that the math is simple and you only need to do it once per setup. This guide gives you the formula, shows how light schedules and seed type change the total, and walks through examples with clearly labeled sample numbers.

The formula

Cost = watts × hours per day × days ÷ 1,000 × your rate ($ per kWh)

The division by 1,000 turns watt-hours into kilowatt-hours (kWh), which is the unit your utility bills you in. Work it out separately for each stage of the grow, because hours per day change between stages, then add the stages together.

Get an honest wattage number

Use what the device actually draws from the wall, not a marketing "equivalent" figure. A light sold as replacing a much bigger fixture may pull far less power than the number on the box suggests. The most reliable options are a plug-in watt meter or the actual power draw on the manufacturer's spec sheet.

Get your real rate

Your bill shows what you pay per kWh. Some utilities split energy and delivery charges, and some use tiered or time-of-use pricing, where the rate depends on how much you use or when. If yours does, the hours your light runs can change what each kWh costs, so read your rate plan.

For a sanity check, the U.S. Energy Information Administration publishes average prices. In its Monthly Energy Review, Table 9.8 lists the U.S. average residential price for July 2026 at 18.31 cents per kWh, including taxes. Your own rate may be well above or below that, so use your bill for real planning.

About the example numbers below

To keep the math readable, the examples use a hypothetical 200-watt light and a round example rate of $0.18 per kWh. These are illustrations, not measurements or quotes. Swap in your own numbers.

Light schedules and what they cost per day

Three schedules cover most indoor grows:

Example only: hypothetical 200 W light at an example rate of $0.18/kWh.
ScheduleHours onkWh per dayCost per day
12/12122.4$0.43
18/6183.6$0.65
20/4204.0$0.72

Notice that flowering a photoperiod on 12/12 costs a third less per day than running the same light on 18/6. That matters when you compare seed types.

How seed type changes the run

Seed type sets both the schedule and how many days the light runs. Our autoflower vs. photoperiod guide explains the biology; here's the cost side.

Photoperiod: two stages

Photoperiods grow under a long-day schedule until you switch to 12/12. You choose how long to veg, and the breeder's listing gives a flowering range. Calculate each stage separately.

Example only: 4 weeks veg at 18/6, then 9 weeks flower at 12/12 Veg: 200 × 18 × 28 ÷ 1,000 = 100.8 kWh Flower: 200 × 12 × 63 ÷ 1,000 = 151.2 kWh Total: 252.0 kWh × $0.18 = about $45.36

Fast versions: shorter flower

Fast-version photoperiods are bred to flower sooner. Sweet Seeds, for example, says its F1 Fast Version line flowers one to two weeks sooner than the originals. Using the same example with two fewer weeks in flower:

Example only: 4 weeks veg at 18/6, then 7 weeks flower at 12/12 Veg: 100.8 kWh Flower: 200 × 12 × 49 ÷ 1,000 = 117.6 kWh Total: 218.4 kWh × $0.18 = about $39.31

Autoflowers: one schedule, start to finish

Autoflowers flower on their own timeline, so many growers keep them on one schedule from seed to harvest. The run is often shorter overall, but every day uses the longer schedule.

Example only: 11 weeks at 20/4 200 × 20 × 77 ÷ 1,000 = 308.0 kWh × $0.18 = about $55.44 Example only: 11 weeks at 18/6 200 × 18 × 77 ÷ 1,000 = 277.2 kWh × $0.18 = about $49.90

In these made-up examples, the shorter autoflower run uses more light energy than the photoperiod run, because it never drops to 12 hours. Change the inputs and the answer can flip. That's the point of doing the math with your own numbers rather than assuming "faster means cheaper."

Don't forget everything else that's plugged in

Exhaust and circulation fans often run around the clock. Heaters, dehumidifiers, air conditioners and pumps can rival the light in some setups. Run the same formula for each device, using 24 hours per day for anything that runs constantly.

Add the rest of the equipment

A quick example for a fan that runs all the time:

Example only: 30 W fan, 24 hours a day, 91 days (13 weeks) 30 × 24 × 91 ÷ 1,000 = about 65.5 kWh × $0.18 = about $11.79

Climate equipment is harder to predict because it cycles on and off. A watt meter on the outlet over a few typical days gives you a realistic daily kWh number to multiply by the length of the run.

Season matters here. In a cold room, the light's heat can help in winter, while summer may push you toward extra cooling. Our winter grow tent planning guide covers the seasonal side.

Practical ways to keep the bill sensible

Quick checklist

  • Find your real rate per kWh on your utility bill.
  • Use actual wall draw in watts for each device.
  • Split the grow into stages by schedule and calculate each.
  • Add 24-hour devices like fans separately.
  • Compare seed types with your own numbers, not assumptions.
  • Recheck when your rate or equipment changes.

FAQ

How do I calculate the electricity cost of a grow light?

Multiply the light's actual power draw in watts by the hours it runs per day and the number of days, divide by 1,000 to get kilowatt-hours, then multiply by your electricity rate per kWh.

Should I use the wattage printed on the light's box?

Use the actual power draw if you can. Some products advertise an equivalent wattage that is higher than what they really pull from the wall. A plug-in watt meter or the manufacturer's spec sheet gives a better number.

Is an autoflower grow cheaper to run than a photoperiod grow?

Not automatically. Autoflowers usually have a shorter overall run, but they are often kept on 18 or 20 hours of light the whole time, while photoperiods drop to 12 hours in flower. Run the formula for both plans with your own numbers.

What electricity rate should I use?

Use the rate on your own utility bill, including delivery charges if they are billed per kWh. The EIA's national average is useful as a sanity check, but local rates vary widely and some utilities charge more at certain times of day.

Compare seed banks side by side

See shipping, guarantees, payment options and catalog type for the seed banks we track, in one table.

Open the comparison

Sources and verification

The EIA figure was checked on October 30, 2026. EIA updates these tables monthly; check eia.gov for the current number.